Ningbo Zhongke Kechuang Electrolyzer Design Requirements
| Model | KA1 |
| Hydrogen Production | 1m³/H |
| Oxygen Production | 0.5m³/H |
| Constant Current (A) | 120 |
| Circulating Water Temperature (℃) | 25-70 |
| Circulating Water Volume | 160L/H |
| Cycle Mode | Water Pump Circulation |
| Hydrogen Purity (%) | 99.99 |
| Water Electrolysis Method | MEA |
| Maximum Pressure | 1.6Mpa |
| TDS Anode Water | ≤1 |
| TDS Cathode Water | / |
| Single Cell Voltage (v) | 1.75-2.5 |
| Dimensions (excluding ear connector) | 190*180*190 |
| MEA Effective Area | 125.5*80.5(20) |
| Application Areas | Fuel cell system testingn,Fuel cel backup power supply,Combined heat and power, Semiconductor,Multi-energy complementary independent micro-grids,etc. |